Compuprint 6314 CDL Manual de usuario Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 53
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
CDL Programmer Manual
46
HELLO
HELLO
HELLO
HELLO
HELLO
fig. 34 Example with repeated fields
2.3.7 Incremental fields
It is often necessary to print a series of labels with a progressive number or letter. You can do this
by using the commands
+pii
(
-pii
) and
>pii
(
<pii
) (see sect. 2.1.2.1.1 on page 13). The
p
is used as
a
filler character
that is the most significant positions are filled with the character
p
.
The following examples, the first in
text
format, the second in Basic, give the result shown in fig.
35.
<STX>L<CR>
D11<CR>
PC<CR>
H15<CR>
133300001550200AAA<CR>
<01<CR>
133300001100200AAA<CR>
>01<CR>
133300000650200000<CR>
-01<CR>
133300000200200000<CR>
+01<CR>
Q0005<CR>
E<CR>
OPEN "com1:9600,n,8,1" FOR OUTPUT AS #1
PRINT #1, CHR$(2); "L"
PRINT #1, "D11"
PRINT #1, "PC"
PRINT #1, "H15"
PRINT #1, "1"; "3"; "33"; "000"; "0155"; "0200"; "AAA"
'decreases the previous field by 1 (alphanumerical fields)
PRINT #1, "<01"
PRINT #1, "1"; "3"; "33"; "000"; "0110"; "0200"; "AAA"
Vista de pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 52 53

Comentarios a estos manuales

Sin comentarios